Functional Description
Microcontroller
At power up, the microcontroller configures the encoder chip and loads the
firmware according to the last stored user settings. The user adjustable
parameters are input through a multifunction rotary and toggle switch
combination interface with a preset option of the factory recall settings. All
the functions are remote read/writable through the intraframe control
interface (available in 8900TX/TF/TFN frames). The Fault Reporting
output is pulsed in case of loss of input signal.
Regulator
The input +12 V is stepped down to +5 V and -5 V using an on-board
switched mode drop (buck) regulator. The regulator does not start up until
the main supply voltage reaches approximately 80% of its nominal value.