5-23
3 -rw- 76960 Aug 15 2008 15:58:02 vmetest.vme
252434 KB total (242996 KB free)
File system type of cfa0: FAT32
Setting an Application File Type
Using the BootWare menu
Enter 2 on the file control submenu, and the system displays the following information:
'M' = MAIN 'B' = BACKUP 'S' = SECURE 'N/A' = NOT ASSIGNED
==========================================================================
|NO. Size(B) Time Type Name |
|1 10323352 Aug/20/2008 10:42:42 M cfa0:/main.bin |
|0 Exit |
==========================================================================
Enter file No:
Enter the file sequence number at the prompt above. In this example, type 1 for file main.bin and press
Enter
. The system prompts you to modify the file type:
Modify the file attribute:
================================================================================
|<1> +Main |
|<2> -Main |
|<3> +Backup |
|<4> -Backup |
|<0> Exit |
================================================================================
Enter your choice(0-4)
Enter 1 for +Main (set to type M), 2 for –Main (remove the M type), 3 for +Backup (set to type B), or 4 for
–Backup (remove the B type). For details about the file types, refer to section “Application Files” on
page xx.
Using the CLI
# Change the type of file main.bin from type B to type M+B.
This command will set the boot file. Continue? [Y/N]:y
The specified file will be used as the main boot file at the next reboot on slot 1!
Now, the type of file main.bin is modified as M+B, and the file is specified as the main boot file to be
used at the next startup of the access controller. If a file of type M already exists on the access controller,