H3C Technologies H3C WX5000 Series Access Controllers User Manual
Page 51
5-11
Load File Name :host
:main.bin
Target File Name :target
:main.bin
Server IP Address :192.168.0.1
Local IP Address :192.168.0.10
Gateway IP Address :0.0.0.0
The load file name and the target file name must not exceed 50 bytes.
After modification of the parameters, the system display returns to the BootWare operation Ethernet
submenu.
=====================
|<1> Update Full BootWare |
|<2> Update Extend BootWare |
|<3> Update Basic BootWare |
|<4> Modify Ethernet Parameter |
|<0> Exit To Main Menu |
================================================================================
Enter your choice(0-4):
Enter 1 on the BootWare operation Ethernet submenu.
The system displays:
Loading...................................................................
..........................................................................
.........................................................Done!
20710792 bytes downloaded!
Updating Basic BootWare? [Y/N]Y
Updating Basic BootWare................Done!
Updating Extend BootWare? [Y/N]Y
Updating Extend BootWare..............Done!
After download of the BootWare program file, the system display returns to the BootWare operation
Ethernet submenu.
===================
|<1> Update Full BootWare |
|<2> Update Extend BootWare |
|<3> Update Basic BootWare |
|<4> Modify Ethernet Parameter |
|<0> Exit To Main Menu |
============================================================================
Enter your choice(0-4):
Enter 0 on this menu to return to the BootWare operation submenu:
=========================