Flow template configuration example
Network requirements
Create flow templates and apply them to interfaces.
Configuration procedure
# Create basic user-defined flow template aaa.
[Sysname] flow-template aaa basic smac customer-vlan-id
# Reference user-defined flow template aaa on interface GigabitEthernet 2/1/1.
[Sysname] interface Gigabitethernet 2/1/1
[Sysname-GigabitEthernet2/1/1] flow-template aaa
# Display information about user-defined flow template aaa.
[Sysname] display flow-template user-defined aaa
user-defined flow template: basic
name:aaa, index:1, total reference counts:1
fields: smac customer-vlan-id
# Display information about all user-defined flow templates.
[Sysname] display flow-template user-defined
user-defined flow template: basic
name:aaa, index:1, total reference counts:1
fields: smac customer-vlan-id
user-defined flow template: basic
name:1, index:2, total reference counts:0
fields: service-cos
user-defined flow template: basic
name:2, index:3, total reference counts:0
fields: ip-protocol dscp
# Display information about the user-defined flow templates referenced to interfaces.
[Sysname] display flow-template interface
Interface: GigabitEthernet2/1/1
user-defined flow template: basic
name:aaa, index:1, total reference counts:1
fields: smac customer-vlan-id
# Delete user-defined flow template aaa. As it is being referenced by interface Gigabitethernet 2/1/1,
remove it from the interface first.
[Sysname] interface Gigabitethernet 2/1/1
[Sysname-GigabitEthernet2/1/1] undo flow-template
[Sysname-GigabitEthernet2/1/1] quit
[Sysname] undo flow-template name aaa
ACL rule length limit mode configuration example
Network requirements