beautypg.com

In other installation sites, When the switch is ac-powered – H3C Technologies H3C S5120 Series Switches User Manual

Page 40

background image

32

Figure 39 Ground the switch by burying the grounding conductor into the earth

(1) Grounding screw

(2) Grounding cable

(3) Earth

(4) Joint

(5) Grounding conductor

(6) Switch rear panel

In other installation sites

When the switch is AC-powered

For an AC-powered switch, if neither of the above-mentioned two conditions is available, ground the

switch through the PE wire of the AC power supply. Make sure the PE wire is well connected to the ground

at the power distribution room or AC transformer side, the switch PE terminal and the PE wire are well

connected, and the three-wire input cable of the grounding cable is used for the power supply cable. If

the PE wire of the AC power supply is not grounded at the power distribution room or AC transformer side,

report the problem and make reconstructions.

Figure 40 Ground through an AC power PE wire

(1) Three-wire AC power input cable

(2) Switch rear panel

NOTE:

Use the grounding cable provided with the switch to connect the grounding strip in the equipment room.
Otherwise, the grounding effect may not be ensured, which easily causes damage to the switch.