CAUTION:

Only the RPS recommended by H3C can be used for the H3C S5120-28P-HPWR-SI. The –48 VDC
power supply in the equipment room cannot be used directly. Otherwise, the device may be

damaged.

Cooling system

The H3C S5120-28P-HPWR-SI is equipped with six fans for heat dissipation.

Ports

Console port

Each S5120-SI series provides one console port on the front panel.

Table 3 Console port specifications

Item Specification

Connector type

RJ-45

Compliant standard

EIA/TIA-232

Transmission baud rate

9600 bps to 115200 bps (defaulting to 9600 bps)

Service

It can be connected to an ASCII terminal.

It can be connected to a serial port of a local or remote (through a pair
of modems) PC running terminal emulation program.

10/100/1000Base-T Ethernet port

Each S5120-SI series provides 10/100/1000Base-T Ethernet ports on its front panel. Quantity of Ethernet

ports varies with the device model. For more information, see

Table 1

.

Table 4 S5120-SI series 10/100/1000Base-T Ethernet port specifications

Item Specification

Connector type

RJ-45

Interface speed and operating
mode

10 Mbps, full duplex

100 Mbps, full duplex

1000 Mbps, full duplex

MDI/MDI-X, auto-sensing

Max transmission distance

100 m (328.1 ft.)

Transmission medium

Category-5 unshielded twisted pair cable

Standard

IEEE 802.3i, IEEE 802.3u, IEEE 802.3ab