Figure 34 Wall mounting

(1) Installation hole

CAUTION:

When mounting the switch, keep the Ethernet ports of the switch facing downwards and the two sides with
ventilation holes vertical to the ground.

Mounting the switch through magnet mounting

The S5120-9P-SI, S5120-9P-PWR-SI and S5120-9P-HPWR-SI support magnet mounting.

Introduction to magnetic mounting accessories

A set of magnetic mounting accessories comprises one permanent magnet and one M3*6 countersunk

head screw, as shown in

Figure 35

. Four sets of magnetic mounting accessories are needed for each

switch.

Figure 35 Magnet and countersunk head screw

(1) Permanent magnet

(2) M3*6 countersunk head screw

Installation procedure

Follow these steps to complete magnet mounting:

Step1

As shown in

Figure 36

, use a Phillips screwdriver to pass the countersunk head screw through the round

hole at the center of the permanent magnet, fasten it to a blind nut in the dent of the switch bottom, and

make sure that the permanent magnet and the switch are fastened reliably.