Airaid 400-140-2 User Manual
Page 2

Airaid Filter Co. 2688 E Rose Garden Ln. Phoenix AZ 85050 (800) 498-6951
REV.10.22.13
P/N 790-551 Aerosol Spray
P/N 790-550 Squeeze Spray
Thank you for purchasing the Airaid Intake System. Contact Airaid @ (800) 498-6951 8:00 AM - 5:00 PM MST weekdays for questions regarding fit or instructions
that are not clear to you. Your Airaid Intake System was carefully inspected and packaged. Check that no parts are missing, or were damaged during shipping. If any parts are
missing, contact Airaid. The air filter element is protected from direct exposure to water and debris; care should be taken not to drive through deep water. WATER INGESTION
IS THE DRIVERS RESPONSIBILTY! The air filter is reusable and should be cleaned periodically.
13. Install the urethane hump hose (#6) onto the air filter
adapter (#2) with two #72 hose clamps (#24), leave the
clamps loose for now. Slide the Airaid Intake Tube into the
hump hose first and then onto the throttle body.
15. While gently lifting on the tube next to the radiator, and
pushing down on the tube over the throttle body, tighten the
two button head bolts on top of the mounting brackets. This
will help make sure the Airaid Intake Tube is sealing on the
throttle body.
14. Install the two brackets (#7, #8) from the Airaid Intake
tube onto the intake manifold using two ¼ -20 x 1/2” button
head bolts (#14), and ¼” flat washers (#15) on the tube, and
four 6mm bolts (#16), and ¼” flat washers (#15) on the bot-
tom. Leave the button head bolts loose for now.
Button Head Bolt
16. Install the L-shaped bracket (#25) using one ¼ -20 x
1/2” button head bolt (#14) and ¼” flat washer (#15) thru
the oval slot into the backside of the tube. Next, install one
6mm bolt (#16) and ¼” flat washer (#15) thru the round
hole into the factory bracket. Tighten the hose clamps on
the hump hose. Some adjustment of the factory bracket
may be necessary for a proper fit, see step #17.
18. Slip the black plastic hose mount (#26) over the radiator
overflow hose. Next, place one ¼” flat washer (#15) over the
hole on the inner drivers side fender. Slide the hose mount
prongs thru the fender and thru the washer.
17. Factory tolerances may require adjusting the factory
bracket to align the tube and hump hose with the filter adapt-
er. Therefore, it may be necessary to loosen the two mount-
ing nuts with a 13mm deep socket, and adjust it.
19. Install the Airaid Premium Filter (#1) onto the air filter
adapter (#2), and tighten the clamp. Next install the weather
strip (#9) onto the top of the CAD as shown. (Hint: start at
one end of the CAD and work towards the other end).
21. Double check your work!
Make sure there is no foreign material in the
intake path. Make sure all clamps, hoses,
bolts, and screws are tight.
22. Reconnect the negative battery
cable!
20. Re-connect the breather hose to the Airaid Intake Tube,
and the MAF sensor wiring harness to the sensor. Refer to
step #1.
Pull up
Push down
6mm
Full color instructions can be viewed on our web site at Airaid.com. Use the Product Search function to find your part number, and click View Details.
FILTER IDENTIFICATION
700-469 Airaid Oiled Media 701-469 Airaid SynthaMax Dry Media - Red
702-469 Airaid SynthaMax Dry Media - Black 703-469 Airaid SynthaMax Dry Media - Blue
For your Oiled media filter we
suggest using the AIRAID Filter
Tune-Up Kit!
Synthamax Air Filters do not require oil.
Service air filter as needed by cleaning
with common non-petroleum all-purpose
household cleaner and water. Simple
Green®, Formula 409® or equivalent
works great. Apply cleaner to outside of
air filter and allow to soak. Then flush
filter clean from the inside out with a gar-
den hose and repeat steps if necessary.
Do not apply high pressure water or air
to clean filter. Allow filter to air dry and
reinstall
.