13. Double check your work!
Make sure there is no foreign material in the intake path. Make sure all clamps, hoses, bolts, and screws are tight.
14. Reconnect the negative battery cable!
Airaid Filter Co. 2688 E Rose Garden Ln. Phoenix AZ 85050 (800) 498-6951
REV.12.3.13
12.
Install the weather strip (#4) on the top
of the Quick Fit panels. (Hint: Start at one
end and work all the way to the other end).
11.
Slide the Airaid Premium Filter (#1)
onto the Quick Fit panel tube, and
tighten the hose clamp. Install the fac-
tory intake tube onto the opposite end
of the Quick Fit panel tube, and tighten
the hose clamp. Tighten the speed
clamps on the breather hose, and the
1/2” rubber elbow.
10.
For 2.7L Engines: After installing
the Quick Fit Panels, (Refer to step #7),
connect the breather hose to the factory
elbow at the back of the valve cover
using one #16 speed clamp.
(Factory intake tube removed for in-
struction purposes).
Thank you for purchasing the Airaid Intake System. Contact Airaid @ (800) 498-6951 8:00 AM - 5:00 PM MST week-
days for questions regarding fit or instructions that are not clear to you. Your Airaid Intake System was carefully inspected and
packaged. Check that no parts are missing, or were damaged during shipping. If any parts are missing, contact Airaid. The air
filter element is protected from direct exposure to water and debris; care should be taken not to drive through deep water. WA-
TER INGESTION IS THE DRIVERS RESPONSIBILITY! The air filter is reusable and should be cleaned periodically.
FILTER IDENTIFICATION
700-452 Airaid Oiled Media 701-452 Airaid SynthaMax Dry Media - Red
702-452 Airaid SynthaMax Dry Media - Black 703-452 Airaid SynthaMax Dry Media - Blue
For your Oiled media filter
we suggest using the AIRAID
Filter Tune-Up Kit!
P/N 790-551 Aerosol Spray
P/N 790-550 Squeeze Spray
Synthamax Air Filters do not re-
quire oil. Service air filter as need-
ed by cleaning with common non-
petroleum all-purpose household
cleaner and water. Simple Green®,
Formula 409® or equivalent works
great. Apply cleaner to outside of
air filter and allow to soak. Then
flush filter clean from the inside out
with a garden hose and repeat steps
if necessary. Do not apply high
pressure water or air to clean filter.