FSS Series Fountain Solution Systems

IAE-600

7-4-2

7-second settings

1.) In the operational mode, press the SEL key for 7 seconds until

the display reads P.

2.) Press the up or down keys to scroll through the menu.
3.) To change the value of a parameter, go to the desired

parameter and press SEL.

4.) The value should appear, press the up or down key to change

the value.

5.) Press the SEL key to return to the menu.
6.) To return to operational mode, hold down the SEL key for 7

seconds.

PARAMETERS

DESCRIPTION

VALUE

P

Proportional Band

9.3

I

Integral Time

11

D

Derivative Time

2.1

TC

Cycle Time

10

HYS

Hysteresis

1

TC2

Cycle Time Out #2

9

COOL

PB Coef for Cooling

1.0

db

Deadband/Overlap

0.5

bAL

Balance

50

Ar

Anti-reset

100

LoC

Parameter-Lock

0

P-n2

Input Type

3

P-SL

Lower Limit Input

0

P-SU

Upper Limit Input

100

P-dP

Decimal Point Position

0

P-AH

Alarm Type-1

5

P-AL

Alarm Type-2

5

PUOF

Process Variable Offset

0

SUOF

Setpoint Variable Offset

0

P-FC

Cel or Fernh Selection

F

START

Ramp/Soak Status

OFF

Su-1

1

st

Set Point

0

TM1r

1

st

Ramping Time

0

TM1S

1

st

Soaking Time

0

Su-2

2

nd

Set Point

0

TM2r

2

nd

Ramping Time

0

TM2S

2

nd

Soaking Time

0

Su-3

3

rd

Set Point

0

TM3r

3

rd

Ramping Time

0

TM3S

3

rd

Soaking Time

0

Su-4

4

th

Set Point

0

TM4r

4

th

Ramping Time

0

TM4S

4

th

Soaking Time

0

MOD

Ramp Soak Mode Code

0