FSS Series Fountain Solution Systems
IAE-600
7-4-2
7-second settings
1.) In the operational mode, press the SEL key for 7 seconds until
the display reads P.
2.) Press the up or down keys to scroll through the menu.
3.) To change the value of a parameter, go to the desired
parameter and press SEL.
4.) The value should appear, press the up or down key to change
the value.
5.) Press the SEL key to return to the menu.
6.) To return to operational mode, hold down the SEL key for 7
seconds.
PARAMETERS
DESCRIPTION
VALUE
P
Proportional Band
9.3
I
Integral Time
11
D
Derivative Time
2.1
TC
Cycle Time
10
HYS
Hysteresis
1
TC2
Cycle Time Out #2
9
COOL
PB Coef for Cooling
1.0
db
Deadband/Overlap
0.5
bAL
Balance
50
Ar
Anti-reset
100
LoC
Parameter-Lock
0
P-n2
Input Type
3
P-SL
Lower Limit Input
0
P-SU
Upper Limit Input
100
P-dP
Decimal Point Position
0
P-AH
Alarm Type-1
5
P-AL
Alarm Type-2
5
PUOF
Process Variable Offset
0
SUOF
Setpoint Variable Offset
0
P-FC
Cel or Fernh Selection
F
START
Ramp/Soak Status
OFF
Su-1
1
st
Set Point
0
TM1r
1
st
Ramping Time
0
TM1S
1
st
Soaking Time
0
Su-2
2
nd
Set Point
0
TM2r
2
nd
Ramping Time
0
TM2S
2
nd
Soaking Time
0
Su-3
3
rd
Set Point
0
TM3r
3
rd
Ramping Time
0
TM3S
3
rd
Soaking Time
0
Su-4
4
th
Set Point
0
TM4r
4
th
Ramping Time
0
TM4S
4
th
Soaking Time
0
MOD
Ramp Soak Mode Code
0