Isee drawing above – AEC FSS Series 1.5- 10 HP Fountain Solution Systems User Manual
Page 17
Page 16
FSS Series Fountain Solution Systems
IAE-600
Figure 4
FSS-R Remote Condenser Assembly Models
To convert inches to cm, multiply dimension by 2.54.
Fan(s) d e f
Remote Condenser
Refrigeration g
Each
Totals e f
Overall Dimensions
Connections
Charge
Model
Dia.
Motor
Amps
Air flow Net wt. Length Width Height
Mtg. Discharge Liquid
R-22
Number
in.
hp c
460V Fans
cfm h
lbs. h
‘A’(in.) ‘B’(in.) ‘C’(in.) ‘D’(in.) ODS(in.) ODS(in.) lbs. g
FSS-R5
¾ hp 1 ø
2.4
1
6,450
260
49.8
40.0
1⅛
⅞
3.6
FSS-R7.5
3.7
2
12,400
470
69.8
60.0
1⅛
⅞
3.6
FSS-R10
3.7
2
13,700
510
89.8
80.0
1⅜
1⅛
4.6
FSS-R15
26
⅓ hp 3 ø
5.0
3
20,500
550
129.8
43.0
40.5
120.0
1⅝
1⅛
6.4
FSS-R20
5.9
2
23,000
840
125.0
108.0
10.0
FSS-R25
5.9
2
21,900
860
125.0
108.0
1⅝
16.0
FSS-R30
9.4
3
34,800 1,280
180.0
24.0
FSS-R35
9.4
3
32,900 1,300
180.0
24.0
FSS-R40
30 1 ½ hp 3 ø
12.9
4
46,400 1,690
235.0
45.5
50.0
i
2⅛
29.0
c
ø represents electrical phase; all motors are 1,140 rpm. Multiply hp by 0.746 to convert to kW.
d
All first fan motors (Header Side) are ¾ hp (0.56 kW) single phase variable speed.
e
Multiply 460V amperages by 2.0 for 208-230V amperages.
f
Multiply 460 V amperages by 0.8 for 575 V amperages.
g
Refrigeration charge is for remote condenser only!
h
To convert cfm to cmh, multiply by 1.699. To convert lbs. to Kg, multiply by 0.454.
i
See drawing above.