FSS Series Fountain Solution Systems
Page 21
IAE-600
3
Installation
3-1 Making Electrical Connections
Check serial tag voltage and amperage requirements and make sure
your electrical service conforms. Total running amps for FSS
Series circulators are also found in the specification tables in
Figures 1 through 4 on Pages 14 through 17.
Bring properly sized power leads and ground from a fused dis-
connect (installed by your electrician) to the unit. Use dual-element
fuses in the disconnect switch, sized according to National
Electrical Code recommendations. Note the outline drawings for
egress into the cabinet. Make sure all electrical connections are
tight.
!
WARNING
1. Make sure that electrical connections
comply with all applicable electrical codes.
2. Ground the unit in accordance with NEC
Article 250.
3. Operating voltage must be within plus or
minus ten percent (±10%) of the nameplate
rating.
4. Phase imbalance must be below 10%.