5maintenance, 1 work rules, 2 maintaining pump packages – AEC VacTrac Series Conveying Systems User Manual
Page 85
VacTrac™ Series Conveying Systems
Page 85
Mechanical Components
WH2-605A.4
5
Maintenance
5-1 Work Rules
The installation, operation, and maintenance of this equipment
must follow all applicable work and safety codes for the location
where it is used. This may include, but is not limited to, OSHA,
CSA, NEC, SPI, and other local, national, and international regu-
lations. In addition, you must observe the following specific rules:
;
Read and follow these instructions when installing, operating,
and maintaining your AEC equipment. If the instructions
become damaged or unreadable, you can obtain additional
copies from the Service Department at AEC, Inc.
;
Only qualified people may work on or with this equipment.
;
Work only with approved tools and devices.
;
Turn off and lock out the power switch when maintaining or
servicing your VacTrac system.
;
Disconnect and lock out main power before servicing electrical
equipment.
5-2 Maintaining Pump Packages
AEC VacTrac pump packages need periodic maintenance to
provide long dependable service. Check these elements regularly:
• Maintain a proper oil level in the blower gearbox. The
manufacturer’s brochure (packed with the pump package)
recommends oils, and lists instructions for checking the oil
level.
• Pack blower bearings with high temperature ball bearing
grease and change the oil to the manufacturer’s
recommendations.