VacTrac™ Series Conveying Systems
WH2-605A.4
Mechanical Components
VacTrac Vacuum Receivers
Models: TF301G, TF301U, TF301S, TF601G, TF601U, TF601S
TF302G, TF302U, TF302S, TF602G, TF602U, TF602S
VF301G, VF301U, VF301S, VF601G, VF601U, VF601S
VF302G, VF302U, VF302S, VF602G, VF602U, VF602S
• Bin-Full sensor on flapper dump valve.
• VF receivers with proximity sensor are used with volume-fill
conveying systems.
• TF receivers are used with time-fill conveying systems.
• Available in 3.0 (30) and 6.0 (60) cubic foot sizes (85- and
170-liter sizes).
• Available in mild steel (1) or stainless steel (2).
• Most models available with flange (G), suspension (U), or
silo (S) mounting systems.
• Individually addressed network-capable distributed I/O
control optional.
• Sixteen (16) -mesh stainless steel pellet deflector standard,
glazed polyester, acrylic, and Gore-Tex ® filters optional.
• 2” (50 mm) to 3” (76 mm) check valves and material inlets
for use with single-line Y systems.
• Optional paddle-style level indicator.
• Optional Compressed air filter cleaning controls for
individual vacuum hoppers available.
• Adjustable proximity-type material-level sensor: 24 VDC or
115 VAC available.