beautypg.com

Vactrac vacuum receivers – AEC VacTrac Series Conveying Systems User Manual

Page 18

background image

Page 18

VacTrac™ Series Conveying Systems

WH2-605A.4

Mechanical Components

VacTrac Vacuum Receivers

Models: TF301G, TF301U, TF301S, TF601G, TF601U, TF601S

TF302G, TF302U, TF302S, TF602G, TF602U, TF602S
VF301G, VF301U, VF301S, VF601G, VF601U, VF601S
VF302G, VF302U, VF302S, VF602G, VF602U, VF602S

• Bin-Full sensor on flapper dump valve.
• VF receivers with proximity sensor are used with volume-fill

conveying systems.

• TF receivers are used with time-fill conveying systems.
• Available in 3.0 (30) and 6.0 (60) cubic foot sizes (85- and

170-liter sizes).

• Available in mild steel (1) or stainless steel (2).
• Most models available with flange (G), suspension (U), or

silo (S) mounting systems.

• Individually addressed network-capable distributed I/O

control optional.

• Sixteen (16) -mesh stainless steel pellet deflector standard,

glazed polyester, acrylic, and Gore-Tex ® filters optional.

• 2” (50 mm) to 3” (76 mm) check valves and material inlets

for use with single-line Y systems.

• Optional paddle-style level indicator.
• Optional Compressed air filter cleaning controls for

individual vacuum hoppers available.

• Adjustable proximity-type material-level sensor: 24 VDC or

115 VAC available.