beautypg.com

Power wiring, 115v ac control voltage, 24 vdc control voltage – AEC VacTrac Series Conveying Systems User Manual

Page 72

background image

Page 72

VacTrac™ Series Conveying Systems

WH2-605A.4

Mechanical Components

Figure 32

Typical VTP Series Junction Box Wiring Diagram

T3

T2

T1

J1

L3

L2

L1

95

96 97

98

TEST

TRIPPED

RESET

LEGEND

FIELD WIRING

INTERNAL
WIRING

VS

MTR

3 PHASE / 4 WIRE SERVICE AND

FUSED DISCONNECT SWITCH TO

BE PROVIDED BY CUSTOMER

OL

M

T1

T2

T3

POWER WIRING

FU

FU

FU

L3

L2

L1

5 H.P. PUMP

OL

L2

L3

L1

FOR PUMP VACUUM/VENT

FOR PUMP MOTOR STARTER

FROM CONTROLLER OUTPUT

FROM CONTROLLER OUTPUT

BLOWBACK SOLENOID

FOR FILTER CHAMBER

FROM CONTROLLER OUTPUT

SOLENOID

115VAC

115V AC CONTROL VOLTAGE

0L

96

95

J1

SOL B

SOL A

M

A2

A1

VS

N.O.

ON FILTER CHAMBER

BLOWBACK SOLENOID

MOTOR STARTER

SOLENOID ON PUMP

VACUUM PUMP

VACUUM/VENT

TO CONTROLLER INPUT

FOR PUMP HIGH VACUUM

NEUTRAL

0 VDC

SOL B

BLOWBACK SOLENOID
ON FILTER CHAMBER

VS

96

95

0L

J1

N.O.

SOL A

M

A2

A1

VACUUM/VENT
SOLENOID ON PUMP

VACUUM PUMP
MOTOR STARTER

+24 VDC

24 VDC CONTROL VOLTAGE

TO MOTOR

DISC

GRD

(MTR)

GRD

FROM CONTROLLER OUTPUT
FOR PUMP MOTOR STARTER

FROM CONTROLLER OUTPUT

FROM CONTROLLER OUTPUT

FOR PUMP VACUUM/VENT

BLOWBACK SOLENOID

FOR FILTER CHAMBER

SOLENOID

TO CONTROLLER INPUT

FOR PUMP HIGH VACUUM

WIRE LUG