Mechanical Components

WH2-605A.4

If mounted in the vacuum line, connect the sequence-T valve to a
60 psi to 80 psi (414 kPa to 552 kPa) source of clean, dry,
lubricated compressed air.

Run a

3

/

8

” (9 mm) branch line off the plant air main to the sequence

T valves in your system. Install a

3

/

8

” (9 mm) x

1

/

8

” (3 mm) tee in

the up position near each receiver.

Connect compressed air to the normally open port on top of the
sequence-T valve solenoid valve with a

1

/

8

” (approx. 3 mm) pipe

nipple. Connect the common port to the sequence-T valve using

1

/

4

” (6 mm) poly tube and connectors. See the following for more

information.

Your

3

/

8

” (9 mm) branch supply line should include:

• A shutoff valve for

ON/OFF

control.

• An air filter/pressure regulator with a gauge for pressure

control.

• Mini-lubricators located at each vacuum receiver.

Figure 28

Vacuum Receiver Sequence T-Valve Compressed Air Connections

TO CONTROL

WIRING

(1)

N. C.

(2)

COM.

(3)

N. O.

(1) NORMALLY CLOSED = EXHAUST PORT
(2) COMMON = CONNECT TO VALVE

(3) NORMALLY OPEN = CONNECT TO AIR SUPPLY