Mechanical Components

Your

3

/

8

” (9 mm) branch supply line should include:

• A shutoff valve for

ON/OFF

control.

• An air filter/pressure regulator with a gauge for pressure

control.

• Mini-lubricators located at each vacuum receiver.

Install a quick-disconnect fitting or a shutoff valve in the
compressed air piping leading to the vacuum receiver atmospheric
valve to speed receiver cover removal for cleanout or service.

Figure 27

Vacuum Receiver Atmospheric Valve Compressed Air Connections

TO CONTROL

WIRING

(1)

N. C.

(2)

COM.

(3)

N. O.

(1) NORMALLY CLOSED = CONNECT TO AIR SUPPLY
(2) COMMON = CONNECT TO VALVE

(3) NORMALLY OPEN = EXHAUST PORT

3-25 Connecting Vacuum Receivers with Sequence-T

Valve Compressed Air Lines

See Figure 12 on Page 27 for an illustration of a typical sequence-
T valve. Critical dried resin systems sometimes require sequence-T
valves to prevent drawing humid atmospheric air into the material
supply. Sequence-T valves are usually installed in the vacuum
header above the vacuum hoppers.

Note: The sequencing valve is located in the cover on SR Series

vacuum receivers if you selected the internal sequencing
valve option.