beautypg.com

AEC VacTrac Series Conveying Systems User Manual

Page 70

background image

Page 70

VacTrac™ Series Conveying Systems

WH2-605A.4

Mechanical Components

When adjusting, fill a vacuum hopper to see if the switch detects
your material. The LED on the switch goes out when it detects
material
.

„

For increased sensitivity, turn the potentiometer clockwise.

„

For decreased sensitivity, turn the potentiometer

counterclockwise.

3-33 Adjusting Sight Glass Proximity Sensor

Sensitivity

You can adjust the sensitivity of the material level proximity
sensor in the sight glass. The factory setting usually is correct for
most applications. The sensor is factory-installed to the frame;
however, you should install the sensor at the material level height
you want.

When adjusting, fill the glass and verify that the sensor detects
your material. The LED on the switch goes out when it detects
material
.

„

For increased sensitivity, turn the potentiometer clockwise.

„

For decreased sensitivity, turn the potentiometer

counterclockwise.

3-34 Connecting the Control Panel to the Pump

Package

Figures 33 to 38

• Wire the pump package motor starter coil (

M

) to the terminal

provided in the VacTrac control panel enclosure.

• Wire the pump package vacuum relief valve solenoid (

SOL

A

) to the terminal provided in the VacTrac control panel

enclosure.

• Wire the pump package high vacuum switch (

VS

) to the

terminal located in the VacTrac control panel enclosure.