5.7.8 Data Defining Pseudo-Instruction (.codeword)

.codeword pseudo-instruction

Instruction format

.codeword

[, ...,]

:

12-bit data
• Only decimal, binary and hexadecimal numbers can be described.
• The data that can be specified are from 0 to 4096 (0xfff).
• One or more spaces or tabs are necessary between the instruction and the first data.
• A comma (,) is necessary between one data and another.

Sample description:

.code

.codeword

0xa,0xa40,0xff3

Function

Defines the 12-bit data to be written to the program ROM.

Precaution

The .codeword pseudo-instruction can be used only in a CODE section.