(S1C60/62 FAMILY ASSEMBLER PACKAGE)

CHAPTER 9: DEBUGGER

tim

(time or step mode)

Function

This command selects a measurement mode of the execution counter during target program execution
by the g (go) or gr (go after reset) command. Either execution time count mode or step count mode
can be selected.

Format

>tim

(direct input mode)

Example

>tim

Set step count mode.

... This command toggles the measurement mode.

>tim

Set real time count mode.
>

Note

The execution time count mode is set at power on by default.

GUI utility

[Option | Mode Setting…] menu item

When this menu item is selected, a dialog box appears allowing selection of a measurement mode.

Use the radio buttons for this selection.