Item Description

and #, *.

PS: If account registers fail, it will not be switched.

Auto Dial Time

Default is 5 seconds

, the option range is 3 to 9 seconds. ATA will

dial out automatically when user didn’t enter any digit within this
time period.

Use # as send
key

Default is Enable. Define [#] as end of dialing key.
Enable: When ATA received [#], it will dial out immediately. (no

need wait for the auto dial out time).

Disable: follow [Auto Dial Time] time to dial out.

# Format is %23 Default is Disable; Use [#] word to send %23 singal. Provide

drop-down options: Disable, Enable.

Auto PSTN

backup

Default is Disable. Provide PSTN auto backup function. When SIP

account register to SIP Server fail, FXS port was switched to
PSTN line automatically if ATA was set to enable. In the
meantime, the FXS port’s dial tone was generated from PSTN
line.

* Please make sure the PSTN line connect to ATA correctly if you

want to enable this function.

PSTN feature

Code

Default is 0*

. This code is to switch the route to PSTN port

manually. When you dial 0* you will hear dial tone from PSTN
line and the call will dial out through PSTN line.

Maximum length

is 7 digits. It only allows to enter number, * and # digits.

Routing Type

Default is “Disable” (OFF) and provide

IP, FXO

, and Disable

features. The call behavior is based on Routing Rule. According
to the routing rule, IP or FXO dail out function can be selected.

Routing Rule

“D” is a dropping prefix function and "+" is used to add multiple
routing rule.

Example: Routing rule is D007+009.

1. When the entered numbers start with 007, such as
00782280220, the condition is satisfied with

D007

. The routing

rule first drops 007 and replace the numbers with 82280220.
Then refer to the “

Routing To

” setting to select the dialing route.

2. When the entered numbers start with

009

, such as

00982280220, the condition is satisfied with

009

. The routing

rule will not drop any prefix, and then refer to the “Routing To”
setting to select the dialing routes.

Submit