Welltech VoIP ATA series V.303 User Manual
Page 107

ATA Web user guide
Welltech Technology Co., Ltd.
107 / 114
2015/1/8
Item Decription
Hi-Tone Freq
Default: 480; This column can only enter numbers; maximum
length is 4 bytes with a range of 0~4096.
Lo-Tone Freq
Default: 440; This column can only enter numbers; maximum
length is 4 bytes with a range of 0~4096.
Hi-Tone Gain
Default: 15360; This column can only enter numbers; maximum
length is 5 bytes with a range of 0~65535.
Lo-Tone Gain
Default: 15360; This column can only enter numbers; maximum
length is 5 bytes with a range of 0~65535.。
On Time 1
Default: 200; Set up the first category of ON time.
This column can only enter numbers; maximum length is 3 bytes
with a range of 0~ 999 (10ms).
Off Time 1
Default: 400; Set up the first category of OFF time.
This column can only enter numbers; maximum length is 3 bytes
with a range of 0~ 999 (10ms).
On Time 2
Default: 0; Set up the second category of ON time.
This column can only enter numbers; maximum length is 3 bytes
with a range of 0~ 999 (10ms).
Off Time 2
Default: 0; Set up the secondsond category of OFF time.
This column can only enter numbers; maximum length is 3 bytes
with a range of 0~ 999 (10ms).
On Time 3
Default: 0; Set up the third category of ON time.
This column can only enter numbers; maximum length is 3 bytes
with a range of 0~ 999 (10ms).
Off Time 3
Default: 0; Set up the third category of OFF time.
This column can only enter numbers; maximum length is 3 bytes
with a range of 0~ 999 (10ms).
Call Waiting
Set up the Call Waiting Tone Settings.
Cadence On
Default: Enable; When check the box, Cadence On will Enable.
Hi-Tone Freq
Default: 440; This column can only enter numbers; maximum
length is 4 bytes with a range of 0~4096.
Lo-Tone Freq
Default: 350; This column can only enter numbers; maximum
length is 4 bytes with a range of 0~4096.
Hi-Tone Gain
Default: 2261; This column can only enter numbers; maximum
length is 5 bytes with a range of 0~65535.
Lo-Tone Gain
Default: 1130; This column can only enter numbers; maximum
length is 5 bytes with a range of 0~65535.
On Time 1
Default: 30; Set up the first category of ON time.
This column can only enter numbers; maximum length is 3 bytes
with a range of 0~ 999 (10ms).
Off Time 1
Default: 20; Set up the first category of OFF time.
This column can only enter numbers; maximum length is 3 bytes
with a range of 0~ 999 (10ms).
On Time 2
Default: 30; Set up the secondsond category of ON time.
This column can only enter numbers; maximum length is 3 bytes
with a range of 0~ 999 (10ms).
Off Time 2
Default: 400; Set up the secondsond category of OFF time.
This column can only enter numbers; maximum length is 3 bytes
with a range of 0~ 999 (10ms).
On Time 3
Default: 0; Set up the third category of ON time.
This column can only enter numbers; maximum length is 3 bytes