7 tones setting, 1 function, 2 instruction – Welltech WellGate M1 User Manual
Page 50
WellGate M1 Web user guide
Welltech Technology Co., Ltd.
50 / 58
2014/12/1
9.7 Tones Setting
9.7.1 Function
Tone setting provides Dial, Ring Back, Busy, Congestion, Ring, Call Waiting Tone and
Multi-Frequency configuration.
9.7.2 Instruction
Item
Description
Dial Tone
Dial tone configuration.
Cadence On
Default is disable.
Hi-Tone Freq
Default is 440. Only numerals are acceptable. Data range:
(0~4096). Maximum length: 4 bytes.
Lo-Tone Freq
Default is 350. Only numerals are acceptable. Data range:
(0~4096). Maximum length: 4 bytes.
Hi-Tone Gain
Default: 4522; Only numerals are acceptable. Data range:
(0~65535). Maximum length: 5 bytes.
Lo-Tone Gain
Default: 2261; Only numerals are acceptable. Data range:
(0~65535). Maximum length: 5 bytes.
On Time 1
Default is 0; The unit is 10ms; Only numerals are acceptable.
Data range: 0~
999, Maximum length: 3 bytes.
Off Time 1
Default is 0; The unit is 10ms; Only numerals are acceptable.
Data range: 0~
999, Maximum length: 3 bytes.
On Time 2
Default is 0; The unit is 10ms; Only numerals are acceptable.
Data range: 0~
999, Maximum length: 3 bytes.
Off Time 2
Default is 0; The unit is 10ms; Only numerals are acceptable.
Data range: 0~
999, Maximum length: 3 bytes.
On Time 3
Default is 0; The unit is 10ms; Only numerals are acceptable.
Data range: 0~
999, Maximum length: 3 bytes.
Off Time 3
Default is 0; The unit is 10ms; Only numerals are acceptable.
Data range: 0~
999, Maximum length: 3 bytes.
Ring Back
Ring back tone configuration.
Candence On
Default is enable