Chapter 1. Safety Information and Technical Specifications

707097-001

1-3

To avoid personal injury and property damage, please carefully follow all the
safety steps listed below:

Before accessing the chassis:

1. Turn off all peripheral devices connected to the server.
2. Press the power button to power off the system.
3. Unplug all power cords from the system or the wall outlets.
4. Disconnect all the cables and label the cables for easy identification.
5. Use a grounded wrist strap designed to prevent static discharge when handling

components.

Removing the chassis covers:

After completing the above steps, you can remove the covers and install
components/peripheral devices into the chassis as described in Chapter 2.

1. Unlock and remove the screws and fasteners to remove the cover or

components.

2. Save all the screws and fasteners for later use. (If necessary, label these screws

or fasteners for easy identification.)

3. Follow the instructions given in Chapter 2 to remove the chassis covers.

Reinstalling the chassis covers:

To maintain proper system cooling and airflow, do not operate the system without
installing all chassis covers back to the chassis. To reinstall the chassis covers,
please follow the steps listed below:

1. Make sure that all components and devices are securely fastened on the chassis

and there are no loose parts/screws inside the chassis.

2. Make sure that all cables are properly connected to the connectors and ports.
3. Use the original screws or fasteners to install the covers to the chassis.
4. Be sure to lock to the chassis or the system to prevent unauthorized access.
5. For proper cooling, enclose the chassis with covers before operating the system.

Before installing the chassis into a rack:

1. Make sure that the rack is securely anchored onto a unmovable surface or

structure before installing the chassis into the rack.

2. Unplug the power cord(s) of the rack before installing the chassis into the rack.
3. Make sure that the system is adequately supported. Make sure that all the

components are securely fastened to the chassis to prevent components falling
off from the chassis.

4. Be sure to install an AC Power Disconnect for the entire rack assembly and

this Power Disconnect must be clearly marked.

5. The rack assembly shall be properly grounded to avoid electric shock.
6. The rack assembly must provide sufficient airflow to the chassis for proper

cooling.