beautypg.com

System fan failure, Accessing the front chassis fans, Replacing system cooling fans – Visara iCON-XT Installation User Manual

Page 32: System fan failure -10

background image

3-10

707097-001

ICON-XT Server - Installation and Maintenance Manual

System Fan Failure

The fans run at 4300 rpm. If a fan fails, the ambient air temperature in the chassis will
rise and activate the overheat LED on the control panel. Replace any failed fan
immediately. The hot plug fans will start to function upon connection to its fan header
on the motherboard.

Accessing the Front Chassis Fans

Procedures

1. Press the release tab located on the left side of the front chassis fan (when facing

the front side of the fan) to release the chassis fan from its locking position as
shown in the picture below:

1

2

2. Once you've loosened the front chassis fan, you can pull the fan out.

Replacing System Cooling Fans

Installing a new fan: (4 each 9.2 cm. Fans)

Replace the failed fan with an identical 9.2-cm, 12 volt fan (Visara p/n 53925-002).

1. Position the new fan at its proper place in the chassis by fitting the fan with its

housing onto the fan mounts in the chassis.

2. A “click” can be heard if the fan (in its housing) is properly installed. If the system

power is on, the hot-pluggable fan feature will cause the fan to start immediately
upon being connected to its header on the motherboard.