Ddsdtesendcode: (read-write), Ddsdteloopconfig: (read-write), Ddsdtestatus: (read-only) – Verilink PRISM 41TDM (34-00275.4) Product Manual User Manual
Page 69: Ddsdteinterfacetype: (read-only), Ddsdtev54loop: (read-write)

DDS 61
ddsDteStopBitNotAvail(3) - Stop bit information is not available. The DTE
interface is probably configured for synchronous operation.
ddsDteSendCode: (read-write)
Allows you to start or verify the setting of the DTE BERT. This variable describes
what type of test code is being sent from the DDS unit back towards the DTE.
ddsDteSendNoCode(1) - Normal data mode of operation
ddsDteSendOtherPattern(2) - Sending some other stress pattern than 511
ddsDteSend511Pattern(3) - Sending 511 stress pattern toward the DTE
ddsDteLoopConfig: (read-write)
Allows you to set a DTE loop or verify the status of a DTE loop
ddsDteNoLoop(1) - Normal data mode of operation
ddsDteV54Loop(2) - Data is looped back toward the DDS network and toward
the DTE loop activated via V.54 loop codes
ddsDteDataLoop(3) - Data is looped back toward the DTE loop activated via
data loop code received from the network
ddsDteOtherLoop(4) - DTE interface has some loop other than one of the
above listed loops active
ddsDteFarEndV54Loop(5) - The far end unit has a V.54 loop current on it's
DTE interface
ddsDteStatus: (read-only)
Reports the current operations status of the DTE interface
ddsDteNoAlarm(1) - DTE interface has no current alarms
ddsDteDtrAlarm(2) - DTE interface has currently declared a loss of DTR
alarm
ddsDteInterfaceType: (read-only)
Reports the DTE interface type being used
ddsDteInterfaceV35(1) - DTE interface is a V.35
ddsDteInterface232(2) - DTE interface is a RS232
ddsDteInterfaceOther(3) - DTE interface is something other than listed above
ddsDteInterfaceNotAvail(4) - DTE interface type is not available
ddsDteInterface530(5) - DTE interface is an EIA-530
ddsDteV54Loop: (read-write)
Allows you to select or verify the operational state of the V.54 option
ddsDteV54LoopEnabled(1) - The unit will currently respond to V.54 loop
codes