Page 33: Bert, Loop mode bert function

Diagnostics 25
Diagnostics
The Diagnostics screen allows testing functions to be performed on the network or
the DTE port. The unit recognizes inband loopback requests as well as local testing
and remote network management loopback test commands. The PRISM 41TDM
has an internal 511 pattern generator and comparator. The unit can transmit the
pattern toward the DDS line/network or toward the data port/DTE interfaces. Bit
Error Rate testing is available on Port B only when the unit is set to TDM mode.
shows the Diagnostics menu structure.
Loop Mode
Allows choosing how data is looped back. The options are Bidirectional and
Unidirectional.
BERT Function
The following menus offer selections for starting a BERT (Bit Error Rate Test)
along with test results.
BERT
This selection allows setting the BERT to Off, Net, DTE A - Net, DTE A - DTE,
DTE B - Net, or DTE B - DTE.
Off - Shuts down any BERT currently running.
Net - Initiates a full bandwidth BERT towards the DDS network. Because the
BERT takes up the entire DDS bandwidth, the FDL function (if active) is
interrupted.
DTE A - Net - In DDS-I or DDS-II mode, there is no discernible difference
between this selection and Net. However, in TXP-I or TXP-II mode, this menu
selection initiates a BERT that does not interfere with the FDL (or other DTE port,
if active).
DTE A - DTE - Initiates a BERT towards the DTE port A. DTE port B (if in TDM
mode) is not affected.
DTE B - Net - In DDS-I or DDS-II mode, there is no discernible difference
between this selection and Net. However, in TXP-I or TXP-II mode, this menu
selection initiates a BERT that does not interfere with the FDL (or other DTE port,
if active).
Table 3-6 Diagnostic Menu
Loop
Mode
BERT
Function
Local
Loop
Far V.54
Loop
V.54
Loop
DTE-A
Loop
DTE-B
Loop
Uni
Bi
BERT
Reset
Sync
Loss
Errored
Seconds
Bit Error
Time
Sync
Off
On
Off
On
Off
On
Off
On
Off
On
Off
Net
DTE A - Net
DTE A - DTE
DTE B - Net
*
DTE B -
DTE
*
Yes
No
display
only
display
only
display
only
HH:MM:SS
display only
In Sync (display only)
No Test (display only)
*
TDM mode only.