Ddsnetremcomm: (read-only), Ddsnetcircuitassur: (read-write), Ddsnetantistrtimer: (read-write) – Verilink PRISM 41TDM (34-00275.4) Product Manual User Manual
Page 67: Ddsnetloopmode: (read-write), Ddsdteobjects, Ddsdterate: (read-write), Dds dte objects

DDS 59
ddsNetTimingInt(2) - Unit supplying timing for DDS network interface
ddsNetTimingDTE(3) - Unit dependent upon DTE device for network
interface timing
ddsNetRemComm: (read-only)
Reports status of the remote communications link
ddsNetRemCommEnabled(1) - Remote communications can be carried out
end to end
ddsNetRemCommDisabled(2) - Remote communications are not allowed
ddsNetRemCommNotAvailable(3) - This unit does not support remote
communications
ddsNetCircuitAssur: (read-write)
Allows you to enable or check setting of the circuit assurance option. Circuit
Assurance does not apply to the DDS-II operating mode.
ddsNetCircuitAssurEnabled(1) - Circuit Assurance is enabled and the
integrity of the DDS loop will be maintained
ddsNetCircuitAssurDisabled(2) - Circuit Assurance is disabled
ddsNetCircuitAssurNotAvailable(3) - This unit does not support Circuit
Assurance
ddsNetAntiStrTimer: (read-write)
This variable describes the current setting for the anti streaming timer.
ddsNetAntiStrTimerOff(1)
-
AntiStreaming Timer is off
ddsNetAntiStrTimer10(2)
-
AntiStreaming Timer is set to 10 seconds
ddsNetAntiStrTimer30(3)
-
AntiStreaming Timer is set to 30 seconds
ddsNetAntiStrTimer60(4)
-
AntiStreaming Timer is set to 60 seconds
ddsNetLoopMode: (read-write)
Allows you to review or set Loop Mode to unidirectional or bidirectional
ddsNetLoopModeUnidirectional(1) - Line, Data, and V54 loops will be
unidirectional Local loop will be bidirectional
ddsNetLoopModeBidirectional(2) - All loops will be bidirectional
DDS DTE Objects
ddsDteRate: (read-write)
Allows you to verify or select the DDS DTE data rate. The available rates depend
upon the ddsNetMode, ddsDteMode, and ddsDteFormat settings.
ddsDteRate2400 - 2400bps
ddsDteRate4800 - 4800bps
ddsDteRate9600 - 9600bps