Ftp the flash file, Select a remote node – Verilink NCM 2000 (880-502623-001) Product Manual User Manual
Page 84

Downloading and Broadcasting Firmware
5-14
Verilink NCM 2000
FTP the Flash File
In this example, a flash file containing the firmware upgrade has
already been transferred to the RAM of the local NCM. See
in this chapter.
The Craft interface session is started in the local node NCM, that is,
with the terminal plugged into the Local port or communicating
directly with the local NCM via Telnet.
Select a Remote
Node
Select the Administration menu from the local NCM Main Menu.
O) administration
The Node Administration menu appears. Select
S) node selection
The Node Selection menu appears. Select the node you wish to
upgrade.
[12.13.14.15] [1,1] NCM 2000 > s1
Confirmed:
Selected FAR end node: [12.13.14.17] shelf = 0, slot = 2
The NCM Node Controller shelf/slot display for the remote node
appears:
Figure 5-13 NCM Main Menu
-- VERILINK NCM CONTROLLER : FW Rev 4.17, Dec 30 1997 16:55:20 --
Site Name: Test Remote Access Level: 4
Managing at FAR end node [12.13.14.17] Node ID: 4463
<- SLOT ->
SHELF 1 2 3 4 5 6 7 8 9 10 11 12 13
0 M N [*N] A A A A - - - - - - -
1 M A A A A A A Q Q M - C D R
2 - - - - - - - - - - - - -
3 - - - - - - - - - - - - -
4 - - - - - - - - - - - - -
KEY: A=DIDCSU, B=DIU/DBU, C=CSU, D=DIU, E=SDIU, F=DIU/DDS, G=DHDM,
H=ATM/IMUX, I=IDCSU, J=PEP, K=DAC, L=HLM, M=IMUX, N=NCM, P=DPRI,
Q=QUAD, R=SUBRATE, S=HSM, T=HDM, U=DCSU, V=VCU, X=QPRI
S) shelf/slot O) administration
C) configuration D) diagnostics
P) performance/status A) alarm
B) circuit manager I) manufacturing info
X) exit this screen
A [12.13.14.17] [0,2] NCM 2000 >