Using telnet, Using telnet -2 – Verilink NCM 2000 (880-502623-001) Product Manual User Manual
Page 26

Craft Interface
2
-2
Verilink NCM 2000
2. Set your terminal parameters to the following values:
•
19.2 kbit/s
•
8 data bits
•
no parity
•
one stop-bit
•
no flow-control
NOTE:
Ensure that both hardware flow control and X-On/X-Off flow control are
disabled.
3. Press E
NTER
to get a prompt.
The prompt displays:
pSH+>
The P-shell is a level below the Craft interface program.
To start the Craft interface, type:
craft
You are prompted:
YOUR PASSWORD?
If you’re accessing the node for the first time, press E
NTER
at the
PASSWORD? prompt.
Until you change it, E
NTER
is the default password.
Using Telnet
Accessing the Craft interface via Telnet requires that you have
previously configured the Ethernet IP address and related
parameters. You must also know the IP address of the NCM you
wish to connect to. The Craft interface must be used at least once
to setup the IP address of the NCM before Telnet can be used.
In a shell, terminal, browser or Telnet application window, use a
command similar to the following:
C:\> telnet 192.94.46.54 (substitute the IP address of the desired
NCM)
A message indicates you have connected to the NCM node:
Figure 2-1 Telnet Session Connecting to the NCM Node
Trying 192.94.46.54 ...
Trying 192.94.46.54 ...
Trying 192.94.46.54 ...
Trying 192.94.46.54 ...
Connected to 192.94.46.54.
Connected to 192.94.46.54.
Connected to 192.94.46.54.
Connected to 192.94.46.54.
Escape character is '^]'.
Escape character is '^]'.
Escape character is '^]'.
Escape character is '^]'.
pSOSystem (192.94.46.54)
pSOSystem (192.94.46.54)
pSOSystem (192.94.46.54)
pSOSystem (192.94.46.54)
Copyright (c) Integrated Systems, Inc., 1992.
Copyright (c) Integrated Systems, Inc., 1992.
Copyright (c) Integrated Systems, Inc., 1992.
Copyright (c) Integrated Systems, Inc., 1992.
Welcome to pSOSystem...
Welcome to pSOSystem...
Welcome to pSOSystem...
Welcome to pSOSystem...
pSH+>
pSH+>
pSH+>
pSH+>