beautypg.com

Switching over to the new firmware, Switching over to the new firmware -11 – Verilink NCM 2000 (880-502623-001) Product Manual User Manual

Page 81

background image

Downloading and Broadcasting Firmware

Verilink NCM 2000

5-11

Figure 5-8 NCM Broadcast Result

Press E

NTER

to display the NCM 2000 Download Firmware Menu.

If an ACP card did not receive a good load the Card Re-transmit
function may be used to specifically target that card.

Switching over to

the New

Firmware

Try the new firmware by using the B) ACP broadcast switchover
option.

NOTE: When switching over to the new firmware version, there is a slight

chance of failure to switch in one or a few modules. The user should

check that the switch-over is actually complete. If not, try again.

After a download, the target module cannot be downloaded again
until that module has been restarted (either in the A bank or in the
B bank).

NOTE: Do not attempt to do a switch over before the download has

completed. The card may be left in an inoperative condition.

Alternatively, the user may navigate to a specific card and reset it
individually, or use the switchover to bank B option.

From the Main Menu, select the module you wish to restart (in this
example, a DIDCSU module, which received the firmware
download):

[12.13.14.15] [1,1] NCM 2000 > s

You are prompted:

Enter ‘shelf,slot’ pair or ‘slot’ in current shelf(e.g. 3,4 or 5): > 1,6

The NCM Controller Main Menu appears:

Select the option for node administration:

O

[12.13.14.15] [1,6] DIDCSU 2912 > o

The DIDCSU Controller Administration Menu appears:

<- SLOT ->

SHELF 1 2 3 4 5 6 7 8 9 10 11 12 13

0 - - - - - - - - - - - - -

1 - - Y Y Y Y - - - - - - -

KEY:Y=GOOD, N=BAD

[12.13.14.15] [1,1] NCM 2000 >