beautypg.com

Verilink NCM 2000 (880-502623-001) Product Manual User Manual

Page 38

background image

Craft Interface

2

-14

Verilink NCM 2000

Figure 2-8 Alarm Options Menu

A shelf/slot matrix display of alarm status appears. Each location is
mapped to a slot of a shelf. The meanings of the symbols shown
are listed in

Table 2-2.

The command options available on the

Alarms Menu are described in

Table 2-3

.

Table 2-2 Alarm Menu Key

The following command options are available on the NCM Alarm
Options Menu:

-- NCM 2000 CONFIGURATION MENU (ALARM OPTIONS)--

-- NCM 2000 CONFIGURATION MENU (ALARM OPTIONS)--

-- NCM 2000 CONFIGURATION MENU (ALARM OPTIONS)--

-- NCM 2000 CONFIGURATION MENU (ALARM OPTIONS)--

-- Alarm Conditions --

-- Alarm Conditions --

-- Alarm Conditions --

-- Alarm Conditions --

<- SLOT ->

<- SLOT ->

<- SLOT ->

<- SLOT ->
SHELF 1 2 3 4 5 6 7 8 9 10 11 12 13

SHELF 1 2 3 4 5 6 7 8 9 10 11 12 13

SHELF 1 2 3 4 5 6 7 8 9 10 11 12 13

SHELF 1 2 3 4 5 6 7 8 9 10 11 12 13
0 - - - - - - - - - - - - -

0 - - - - - - - - - - - - -

0 - - - - - - - - - - - - -

0 - - - - - - - - - - - - -
1 M C C - - A A C C C - - - -

1 M C C - - A A C C C - - - -

1 M C C - - A A C C C - - - -

1 M C C - - A A C C C - - - -
2 - - - - - - - - - - - - -

2 - - - - - - - - - - - - -

2 - - - - - - - - - - - - -

2 - - - - - - - - - - - - -
3 - - - - - - - - - - - - -

3 - - - - - - - - - - - - -

3 - - - - - - - - - - - - -

3 - - - - - - - - - - - - -
4 - - - - - - - - - - - - -

4 - - - - - - - - - - - - -

4 - - - - - - - - - - - - -

4 - - - - - - - - - - - - -

Legend: A = In Alarm, B = Alarming Blocked, C = Alarms Clear

Legend: A = In Alarm, B = Alarming Blocked, C = Alarms Clear

Legend: A = In Alarm, B = Alarming Blocked, C = Alarms Clear

Legend: A = In Alarm, B = Alarming Blocked, C = Alarms Clear

M) alarm monitoring: NO

M) alarm monitoring: NO

M) alarm monitoring: NO

M) alarm monitoring: NO
I) relay inhibit

I) relay inhibit

I) relay inhibit

I) relay inhibit
A) display alarm buffer

A) display alarm buffer

A) display alarm buffer

A) display alarm buffer
C) clear alarm buffer

C) clear alarm buffer

C) clear alarm buffer

C) clear alarm buffer
X) exit menu

X) exit menu

X) exit menu

X) exit menu

A [12.13.14.15] [1,2] NCM 2000 >

A [12.13.14.15] [1,2] NCM 2000 >

A [12.13.14.15] [1,2] NCM 2000 >

A [12.13.14.15] [1,2] NCM 2000 >

Symbol

Meaning

-

NCM sees no card in this slot.

A

Card has some alarm condition at this time, use A) display alarm

buffer to view current alarm details.

B

The Relay Inhibit option has been configured not to show alarms

for a period of time, and this screen has been displayed during

this inhibited (blocked) period. Useful if a circuit tends to have

frequent but minor alarms of short duration and the user wants

to avoid relay trips caused by these conditions.

C

Card has no alarms at this time, any previous alarms have

cleared.