Standalone HDM 2180 Management
3-16
Verilink HDM 2180 User Manual
Figure 3-10 DS3 NE Performance Monitoring Menu
To display the data for any of the parameters listed in the DS3
NE Performance Monitoring Menu, type the letter command
for that particular parameter.
Table 3-10 Near End Performance Monitoring Menu Command Choices
--- DS3 NE Performance Monitoring ---
--- DS3 NE Performance Monitoring ---
--- DS3 NE Performance Monitoring ---
--- DS3 NE Performance Monitoring ---
C) 24 hr. LCV
C) 24 hr. LCV
C) 24 hr. LCV
C) 24 hr. LCV
E) 24 hr. LES
E) 24 hr. LES
E) 24 hr. LES
E) 24 hr. LES
S) 24 hr. LSES
S) 24 hr. LSES
S) 24 hr. LSES
S) 24 hr. LSES
V) 24 hr. P-bit CV
V) 24 hr. P-bit CV
V) 24 hr. P-bit CV
V) 24 hr. P-bit CV
R) 24 hr. P-bit CV ES
R) 24 hr. P-bit CV ES
R) 24 hr. P-bit CV ES
R) 24 hr. P-bit CV ES
M) 24 hr. P-bit CV SES
M) 24 hr. P-bit CV SES
M) 24 hr. P-bit CV SES
M) 24 hr. P-bit CV SES
P) 24 hr. C-bit CV
P) 24 hr. C-bit CV
P) 24 hr. C-bit CV
P) 24 hr. C-bit CV
B) 24 hr. C-bit CV ES
B) 24 hr. C-bit CV ES
B) 24 hr. C-bit CV ES
B) 24 hr. C-bit CV ES
I) 24 hr. C-bit CV SES
I) 24 hr. C-bit CV SES
I) 24 hr. C-bit CV SES
I) 24 hr. C-bit CV SES
F) 24 hr. SEFS
F) 24 hr. SEFS
F) 24 hr. SEFS
F) 24 hr. SEFS
A) 24 hr. AISS
A) 24 hr. AISS
A) 24 hr. AISS
A) 24 hr. AISS
U) 24 hr. UAS
U) 24 hr. UAS
U) 24 hr. UAS
U) 24 hr. UAS
L) 24 hr. LOSS
L) 24 hr. LOSS
L) 24 hr. LOSS
L) 24 hr. LOSS
O) 24 hr. LOFS
O) 24 hr. LOFS
O) 24 hr. LOFS
O) 24 hr. LOFS
X) exit
X) exit
X) exit
X) exit
Command Description
C
24 hour LCV—Line Coding Violation. Displays the 24 hour NE LCV performance data
register showing any near-end bipolar violation events or excessive zeros events.
E
24 hour LES—Line Errored Second. Displays the 24 hour NE LES performance data register
that shows any second in which one or more coding violations, or one or more loss-of-
signal errors occurred.
S
24 hour LSES—Line Severely Errored Seconds. Displays the 24 hour NE LSES performance
data register showing the seconds during which the NE was (at any point during the
second) in the AIS state.
V
24 hour P-bit CV—P-bit Coding Violation. Displays the 24 hour NE P-bit CV performance
data register showing the occurrences of a received P-bit code on the DS3 M-frame, not
identical to the corresponding near-end code.
R
24 hour P-bit CV ES—P-bit Errored Seconds. Displays the 24 hour NE P-bit CV ES
performance data register showing the seconds with one or more PCVs, or one or more out
of frame errors or incoming AISs.
M
24 hour P-bit CV SES—P-bit Severely Errored Seconds. Displays the 24 hour NE P-bit CV SES
performance data register showing the seconds with 44 or more PCVs, or one or more Out
of Frame errors or incoming AISs.
P
24 hour C-bit CV—C-bit Coding Violation. Displays the 24 hour NE C-bit CV performance
data register showing the near-end count of C-bit parity errors occurring during the
designated time interval.
B
24 hour C-bit CV ES—C-bit Errored Seconds. Displays the 24 hour NE C-bit CV ES
performance data register showing the near-end seconds with one or more CCVs, or one or
more out-of-frame errors or incoming AISs.
I
24 hour C-bit CV SES—C-bit Severely Errored Seconds. Displays the 24 hour NE C-bit CV SES
performance data register showing the near-end seconds with 44 or more CCVs or one or
more out-of-frame errors or incoming AISs.
F
24 hour SEFS—Severely Errored Framing Seconds. Displays the 24 hour NE SEFS
performance data register which shows the near-end seconds with one or more out-of-
frame defects or incoming AISs.