Regulatory requirements, Regulatory requirements -5 – Verilink HDM 2180 (880-503048-001) Product Manual User Manual
Page 15

HDM 2180 DS3 DSU Overview
Verilink HDM 2180 User Manual
1-5
Table 1-2
Data Port Specifications
Table 1-3
Environmental Specifications
Regulatory
Requirements
This product complies with the following regulatory specifications
as they apply to telecommunications equipment:
•
FCC—Part 15, Subpart J, Class A: Computing devices
•
15.810: Radiated Emission
Input Signal
-11.7 dBm to +6.2 dBm, level DS3
Output Signal
-4.7 dBm to +3.6 dBm (DSX-3 cross-connect point)
Impedance
75
Ω
± 5%
Connector
BNC female, one each for TX and RX
System Timing
T3 (BNC), Network, or Internal
Data Ports
Type
HSSI, DCE only
Line rate
n
×
1.578 Mbit/s, where n = 1 to 28
Physical interface
50-pin HSSI
Hardware handshake
Control leads supported for DTR, DSR, TM, LLA, LLB
Non-operating
Temperature range
-20 to + 80
°
C
Maximum
temperature change
rate
8
°
C
per hour
Humidity
0% to 95% relative, non-condensing
Vibration, in
transport, withstand
0.5 G from 5 Hz
3.0 G from 50 Hz to 500 Hz
Shock during
shipping, withstand
20 msec, 25 G, half-sine shock pulse when mounted normally
80 G peak, half sine for 10 msec
Operating
Power consumption
<15 Watts total, front and back modules
Temperature range
0 to 50
°
C
, 0% to 95% relative humidity, non-condensing
Vibration
Withstand 25 G @ 1 to 60 Hz with no service interruption