Hdm 2180 quick set-up, Installation, Installation -1 – Verilink HDM 2180 (880-503048-001) Product Manual User Manual
Page 19: Chapter

Verilink HDM 2180 User Manual
2-1
Chapter
2
HDM 2180 Quick Set-Up
This chapter provides step-by-step procedures for setting up your
HDM 2180 module. This quick configuration guide makes the
following assumptions:
• You are installing the HDM 2180 and an NCM 2000 module in a
Dual-line Shelf. Two external PWR 2940 power supplies will be
used.
• You are putting a router on the HSSI port of the HDM 2180 that
outputs data at 43 Mbit/s.
• You are connecting a full T3 to the DS3 port.
NOTE: The NCM 2000 controller module MUST be installed in Slot 2
of the shelf. The HDM 2180 MUST be installed in Slot 1 of the
shelf. When an HDM 2180 and an NCM 2000 are used in a
Dual-line shelf, two external power supplies are required.
Figure 2-1
Example Configuration
NOTE: These procedures may not match your configuration. Use this
chapter as a guide for equipment installation. Chapter 3 has
complete details on configuration covering all options.
Installation
Do the following before installing the HDM 2180:
• Install all associated Access System 2000 shelves and power
supplies, as outlined in the AS2000: The Basics manual.
• Install and test the NCM module first.
Management
Terminal/PC
Full T3
NCM 2000
HDM 2180
DS3 Port
Router
HSSI Port to
43 Mbit/s