Start channel, Channel, T1 dte configuration – Verilink FrameStart FSD (34-00291.F) Product Manual User Manual
Page 41: Rate, Dte clock, Txcc clock, Dte data

O p e r a t i o n
35
Start Channel
The starting channel in the 24-channel DS1 bit stream must be selected in
this field. The unit then assigns the following channels automatically
according to the number of channels (#Channel) and the mode selected in
Channels Assigned. The choices are 01 through 24.
#Channel
Selects number of channels to be assigned to the network ranging from 0
through 24.
T1 DTE Configuration
This menu establishes the necessary parameters for connection with the DTE.
Rate
The unit can operate at any data rate that is a multiple of 56 or 64 kbps.
When 64Kbps is selected, the ones density requirements of the T1 network
line must be ensured. When 56Kbps is selected, the unit maintains ones
density for the selected DS0 channel.
DTE Clock
The polarity of the clock is either normal or inverted.
TXCC Clock
This is used to enable or disable generation of the TXCC clock from the unit
to the DTE.
DTE Data
In the invert mode, transmit and receive data are inverted at the port interface.
This function can be used as a means of guaranteeing ones density when the
data is composed of SDLC- type protocols. The default setting is normal.
CTS
Setting this field to Forced On allows the forcing of the port control lead
output state. Normal allows for normal operation where CTS follows the
transition of RTS.
DCD
Setting this field to Forced On allows the forcing of the port control lead