beautypg.com

Maintenance, Loop, Monitor mode – Verilink FrameStart FSD (34-00291.F) Product Manual User Manual

Page 34: None, Enable llb (dds csu/dsu only)

background image

28

D D S C S U / D S U a n d T 1 C S U / D S U a n d F r a m e S t a r t F S E

Monitor Mode.

When the unit is in monitor mode (LM) and LMI Mode is

configured for MON, individual selection of PVC discovery and delay is
allowed by pressing SELECT while in the DLCI screen. Test DLCI xxx? is
displayed. Pressing SELECT performs the test as follows. The unit sets up a
mask for this one circuit and sends PVC discovery and PVC delay
approximately every second. This minimizes the traffic disruption on the
circuit. The screen then returns to the previous performance screen where the
fields are updated when the information is collected. Choosing SELECT again
displays End Test? where SELECT stops the test and the unit goes back to
normal operation. If the unit is scrolled to another DLCI and another test is
enabled, the unit stops the test on the existing DLCI and starts the new DLCI.
Pressing SCROLL takes the unit to the previous performance screen.

The SOS message is displayed as shown in Figure 4.4. This allows the user to
view the local and remote DLCI and unit ID numbers for fault isolation. As
new circuits are added, information is displayed as shown in Figure 4.4.

Figure 4.4

Example DLCI Total Screen in Test

Maintenance

The Maintenance menu allows performing loop tests, BERT functions, and
error counts on the circuit. Loops, BERTs, and error counts are activated and
cleared from the unit. No other test equipment is needed.

Loop

This menu allows running diagnostic loop tests on the network. Figure 4.5
shows normal operation.

Figure 4.5

Normal Operation

None.

Selecting NONE leaves the unit in normal operation and forwards the

unit to BERT.

Enable LLB (DDS CSU/DSU only).

(Line Loopback) - As shown in

Figure 4.7, the received network signal is looped back toward the network.

0037 -> ACT.---

----mS

New Circuit

RCV SOS

IN TEST

Monitor Status

This message appears when an SOS is
received from another unit.

This message appears when unit is in test.

Network

Framer /

Receivers/

BERT

DTE

From

NET

To

NET

To

Port

From

Port

(Winchester-type

Connector)

Drivers

Deframer

Interface

Generator/

Detector

To Network

RJ-48C

From Network