T1 csu/dsu menutree, Figure 4.3 – Verilink FrameStart FSD (34-00291.F) Product Manual User Manual
Page 30

24
D D S C S U / D S U a n d T 1 C S U / D S U a n d F r a m e S t a r t F S E
MAIN MENU
ALARMS
NETWORK:
OK
LOSS
OOFS
AISS
RAS
ES
SES
BES
UAS
BPVS
CSS
CRCES
FR NET
‡
: OK, LOCAL SOS, DLCI
RESET TIMER: 000 – 900, 30
§
RESET ALARMS?
PERFORMANCE
NET PERFORMANCE
RCV LVL: 2 – 7.5 dB, 7.5 – 15 dB, 15 – 22.5 dB, <22.5 dB
LOSS
OOFS
AISS
RAS
ES
SES
BES
UAS
BPVS
CSS
CRCES
CLEAR HISTORY?
FR PERFORMANCE
LMI TYPE: ORIG, ANSI D, ITU A
PCKT SRC: UNI, NI
DLCI TOTAL: 000 –999
†
CLEAR DLCI?
DLCI Screen
TEST DLCI xxx
‡
MAINTENANCE
LOOP:
NONE?, ENABLE LLB?, ENABLE PLB?, ENABLE V54?,
ENABLE RMT V54?, ENABLE RMT LLB?, ENABLE RMT PLB?
BERT: NONE,
EN. NET BERT?
TP: MARKS, SPACES, 511, 2047
EN. IDLE BERT?
INJECT ERROR?
EN. DTE BERT?
ERR CNT = 00000 –65356
EN. CH01 – CH24 BERT?
CLEAR ERR CNT?
NETWORK CONFIG
FRAMING: D4, ESF
LINE CODE: AMI, B8ZS
CLOCK SRC: NET, INT
SENSITIVITY: DIS, EN
LBO: 0 dB,
−
7.5 dB,
−
15 dB,
−
22.5 dB
YEL ALARM: EN, DIS
DENSITY: EN, DIS
FDL: NONE, ANSI, AT&T
CHANNELS: CONT, ALT
START CHAN: 01 – 24
#CHANNELS: 00 – 24
DTE CONFIG
RATE: 56 Kbps, 64 kbps
DTE CLOCK: NOR, INV
TXCC CLOCK: EN, DIS
DTE DATA: NOR, INV
CTS: NORMAL, FORCED ON
DCD: NORMAL, FORCED ON
DSR: NORMAL, FORCED ON
DTR: NORMAL, IGNORED
FRAME RLY CONFIG
LMI MODE: OFF, ON, MON
‡
UNIT ID: 000
–
999
N391: 001 –255, 006
N392: 01 – 10, 03
N393: 01 – 10, 04
T391: 05– 30, 10
PVC MODE: DIS, EN
SOS TX: EN, DIS
‡
SOS RX: EN, DIS
‡
UTILITIES
VERSION: z.zz
RESTORE FACTORY?
SET PASSWORD
*
:
The three-digit current and
threshold values (###/ ###)
range from 000 to 900. An
asterisk (*) to the left of these
values indicates that the
current value has exceeded
the threshold value. Pressing
SELECT on a displayed alarm
allows editing the threshold
parameters for that alarm.
* This field establishes the unit password used for
entering the front panel interface. A password
must be eight characters. SCROLL increments
the characters (0 –9, A–Z, a –z). The cursor
blinks over the character or digit to be selected
or modified. SELECT accepts the current value
and moves the cursor right. When the eighth
character is selected, a verification screen
appears. Reenter the password.
The values are shown
as (sss/ ttttt). The
15-
minute
current value (sss)
ranges from 000 to
900. The 24-hour total
values (ttttt) range
from 00000
to 65535.
Figure 4.3
T1 CSU/DSU Menutree
† (Install mode only) If the DLCI TOTAL is
greater than 000, a screen with the following
format appears when SELECT is pressed:
uuuu -> vvvv:www
xxxxms yyyykbps
uuuu - the local DLCI number
vvvv - ACT., IDLE, NEW, DEL., or REMOTE
DLCI (if discovered)
www - remote unit ID
xxxx - average delay (if discovered)
yyyy - committed information rate
‡ Monitor option only
§ This does not apply to frame relay alarms.
Default values are shown in bold.