beautypg.com

T1 csu/dsu menutree, Figure 4.3 – Verilink FrameStart FSD (34-00291.F) Product Manual User Manual

Page 30

background image

24

D D S C S U / D S U a n d T 1 C S U / D S U a n d F r a m e S t a r t F S E

MAIN MENU

ALARMS

NETWORK:

OK
LOSS
OOFS
AISS
RAS
ES
SES
BES
UAS
BPVS
CSS
CRCES

FR NET

: OK, LOCAL SOS, DLCI

RESET TIMER: 000 – 900, 30

§

RESET ALARMS?

PERFORMANCE

NET PERFORMANCE

RCV LVL: 2 – 7.5 dB, 7.5 – 15 dB, 15 – 22.5 dB, <22.5 dB
LOSS
OOFS
AISS
RAS
ES
SES
BES
UAS
BPVS
CSS
CRCES
CLEAR HISTORY?

FR PERFORMANCE

LMI TYPE: ORIG, ANSI D, ITU A
PCKT SRC: UNI, NI

DLCI TOTAL: 000 –999

CLEAR DLCI?

DLCI Screen

TEST DLCI xxx

MAINTENANCE

LOOP:

NONE?, ENABLE LLB?, ENABLE PLB?, ENABLE V54?,
ENABLE RMT V54?, ENABLE RMT LLB?, ENABLE RMT PLB?

BERT: NONE,

EN. NET BERT?

TP: MARKS, SPACES, 511, 2047

EN. IDLE BERT?

INJECT ERROR?

EN. DTE BERT?

ERR CNT = 00000 –65356

EN. CH01 – CH24 BERT?

CLEAR ERR CNT?

NETWORK CONFIG

FRAMING: D4, ESF
LINE CODE: AMI, B8ZS
CLOCK SRC: NET, INT
SENSITIVITY: DIS, EN
LBO: 0 dB,

7.5 dB,

15 dB,

22.5 dB

YEL ALARM: EN, DIS
DENSITY: EN, DIS
FDL: NONE, ANSI, AT&T
CHANNELS: CONT, ALT
START CHAN: 01 – 24
#CHANNELS: 00 – 24

DTE CONFIG

RATE: 56 Kbps, 64 kbps
DTE CLOCK: NOR, INV
TXCC CLOCK: EN, DIS
DTE DATA: NOR, INV
CTS: NORMAL, FORCED ON
DCD: NORMAL, FORCED ON
DSR: NORMAL, FORCED ON
DTR: NORMAL, IGNORED

FRAME RLY CONFIG

LMI MODE: OFF, ON, MON

UNIT ID: 000

999

N391: 001 –255, 006
N392: 01 – 10, 03
N393: 01 – 10, 04
T391: 05– 30, 10
PVC MODE: DIS, EN

SOS TX: EN, DIS

SOS RX: EN, DIS

UTILITIES

VERSION: z.zz
RESTORE FACTORY?

SET PASSWORD

*

:

The three-digit current and
threshold values (###/ ###)
range from 000 to 900. An
asterisk (*) to the left of these
values indicates that the
current value has exceeded
the threshold value. Pressing
SELECT on a displayed alarm
allows editing the threshold
parameters for that alarm.

* This field establishes the unit password used for

entering the front panel interface. A password
must be eight characters. SCROLL increments
the characters (0 –9, A–Z, a –z). The cursor
blinks over the character or digit to be selected
or modified. SELECT accepts the current value
and moves the cursor right. When the eighth
character is selected, a verification screen
appears. Reenter the password.

The values are shown
as (sss/ ttttt). The

15-

minute

current value (sss)
ranges from 000 to
900. The 24-hour total
values (ttttt) range
from 00000
to 65535.

Figure 4.3

T1 CSU/DSU Menutree

(Install mode only) If the DLCI TOTAL is

greater than 000, a screen with the following
format appears when SELECT is pressed:

uuuu -> vvvv:www

xxxxms yyyykbps

uuuu - the local DLCI number
vvvv - ACT., IDLE, NEW, DEL., or REMOTE
DLCI (if discovered)
www - remote unit ID
xxxx - average delay (if discovered)
yyyy - committed information rate

Monitor option only

§ This does not apply to frame relay alarms.

Default values are shown in bold.