D D S C S U / D S U a n d T 1 C S U / D S U a n d F r a m e S t a r t F S E

Enable Network BERT.

BERTs the full DDS in the DDS and T1 CSU/DSU

bandwidth towards the network.

Enable Idle BERT (T1 CSU/DSU and FrameStart FSE only).

BERTs the

idle (unallocated) channels toward the network.

Enable DTE BERT.

BERTs the DTE.

Enable Channel 01 to 24 BERT (T1 CSU/DSU only).

BERTs the

selected channel towards the network.

Enable Timeslot 01 to Timeslot 31 BERT (FrameStart FSE only).

BERTs the selected channel towards the network.

Test Patterns

This command allows selecting the test pattern. The selections are Marks,
Spaces, 511, and 2047.

Inject Error

This command injects a single error when operating in BERT mode.

Error Count

Displays the number of bit errors that have been detected since the test began
or since error statistics were last cleared.

Clear Error Count

This selection is used to reset the BERT error count.

DDS DTE Configuration

This menu establishes the necessary parameters for connection with the DTE
for the DDS CSU/DSU. The network configuration is automatically set when
the DTE Rate is set. For example, 56 Kbps DTE Rate sets the network to
DDS I and 64 Kbps DTE Rate sets the network to DDS II CC 64K.

Rate

The unit can operate at 56 or 64 kbps.

DTE Clock

The polarity of the clock is either normal or inverted.