Alarms, Framestart fse menutree, Figure 4.3 – Verilink FrameStart FSD (34-00291.F) Product Manual User Manual
Page 31

O p e r a t i o n
25
Alarms
Press SELECT to view the current (within the last 15 minutes) and threshold
alarm status for the network and DTE lines. To change the threshold
parameters, press the SELECT button on its alarm value. Reset capabilities
allow clearing the alarm values.
The three-digit current and threshold values (### /###) range from 000 to 900.
An asterisk (*) to the left of these values indicates that the current value has
MAIN MENU
ALARMS
NETWORK:
OK
LOSS
OOFS
AISS
RAS
ES
SES
DS
UAS
BPVS
CSS
CRCES
FR NET
‡
: OK, LOCAL SOS, DLCI
RESET TIMER: 000 – 900, 30
§
RESET ALARMS?
PERFORMANCE
NET PERFORMANCE
RCV LVL: 2 – 7.5 dB, 7.5 – 15 dB, 15 – 22.5 dB, <22.5 dB
LOSS
OOFS
AISS
RAS
ES
SES
DS
UAS
BPVS
CSS
CRCES
CLEAR HISTORY?
FR PERFORMANCE
LMI TYPE: ORIG, ANSI D, ITU A
PCKT SRC: UNI, NI
DLCI TOTAL: 000 –999
†
CLEAR DLCI?
DLCI Screen
TEST DLCI xxx
‡
MAINTENANCE
LOOP:
NONE?, ENABLE LLB?, ENABLE PLB?,
ENABLE V54?, ENABLE RMT V54?
BERT: NONE,
EN. NET BERT?
TP: MARKS, SPACES, 511, 2047
EN. IDLE BERT?
INJECT ERROR?
EN. DTE BERT?
ERR CNT = 00000 –65356
EN. TS01 –TS31 BERT?
CLEAR ERR CNT?
NETWORK CONFIG
FRAMING: CAS, CCS, FULL 2M
CRC4 MODE: EN, DIS
E-BIT MODE: EN, DIS^
CLOCK SRC: NET, INT
RAI ALARM: EN, DIS
TIMESLT 01: ACT. / IDLE
~
TIMESLT 02: ACT. / IDLE
~
TIMESLT 31: ACT. / IDLE
~
DTE CONFIG
DTE CLOCK: NOR, INV
TXCC CLOCK: EN, DIS
DTE DATA: NOR, INV
CTS: NORMAL, FORCED ON
DCD: NORMAL, FORCED ON
DSR: NORMAL, FORCED ON
DTR: NORMAL, IGNORED
FRAME RLY CONFIG
LMI MODE: OFF, ON, MON
‡
UNIT ID: 000
–
999
N391: 001 –255, 006
N392: 01 – 10, 03
N393: 01 – 10, 04
T391: 05– 30, 10
PVC MODE: DIS, EN
SOS TX: EN, DIS
‡
SOS RX: EN, DIS
‡
UTILITIES
VERSION: z.zz
RESTORE FACTORY?
SET PASSWORD
*
:
The three-digit current and
threshold values (###/ ###)
range from 000 to 900. An
asterisk (*) to the left of these
values indicates that the
current value has exceeded
the threshold value. Pressing
SELECT on a displayed alarm
allows editing the threshold
parameters for that alarm.
* This field establishes the unit password used for
entering the front panel interface. A password
must be eight characters. SCROLL increments
the characters (0 –9, A–Z, a –z). The cursor
blinks over the character or digit to be selected
or modified. SELECT accepts the current value
and moves the cursor right. When the eighth
character is selected, a verification screen
appears. Reenter the password.
The values are
shown as (sss/ttttt).
The
15-minute
current value (sss)
ranges from 000 to
900. The 24-hour
total values (ttttt)
range from 00000
to 65535.
Figure 4.3
FrameStart FSE Menutree
† (Install mode only) If the DLCI TOTAL is
greater than 000, a screen with the following
format appears when SELECT is pressed:
uuuu -> vvvv:www
xxxxms yyyykbps
uuuu - the local DLCI number
vvvv - ACT., IDLE, NEW, DEL., or REMOTE
DLCI (if discovered)
www - remote unit ID
xxxx - average delay (if discovered)
yyyy - committed information rate
‡ Monitor option only
§ This does not apply to frame relay alarms.
Default values are shown in bold.
^ This selection only appears
if CRC4 Mode is set to EN.
~ The TIMESLOT selections do not
appear if Framing is set to FULL
2M. If FRAMING is set to CAS,
TIMESLOT 16 is not displayed.