O p e r a t i o n

23

MAIN MENU

ALARMS

NETWORK:

OK
LOSS, 5
OOSS, 5
BPVS, 0

FR NET

: OK, LOCAL, SOS, DLCI

RESET TIMER: 000 – 900, 30

§

RESET ALARMS?

PERFORMANCE

NET PERFORMANCE

RCV LVL: 0.0 dB, 7.3 dB, 13.6 dB, 19.7 dB, 26.0 dB,

32.3 dB, 38.4 dB, 44.4 dB, 50.5 dB

LOSS
OOSS
BPVS
CLEAR HISTORY?

FR PERFORMANCE

LMI TYPE: ORIG, ANSI D, ITU A
PCKT SRC: UNI, NI

DLCI TOTAL: 000 –999

DLCI Screen

CLEAR DLCI?

TEST DLCI xxx?

MAINTENANCE

LOOP:

NONE?, ENABLE LLB?, ENABLE DLB?, ENABLE LCL
ENABLE V54?, ENABLE RMT V54?, ENABLE RMT DLB

BERT: NONE,

EN. NET BERT?

TP: MARKS, SPACES, 511, 2047

EN. DTE BERT?

INJECT ERROR?
ERR CNT = 00000 – 65356
CLEAR ERR CNT?

DTE CONFIG

RATE: 56 Kbps, 64 Kbps

1

DTE CLOCK: NOR, INV
TXCC CLOCK: EN, DIS
DTE DATA: NOR, INV
CTS: NORMAL, FORCED ON
CTS DELAY: 000 – 255
DCD: NORMAL, FORCED ON
DSR: NORMAL, FORCED ON
DTR: NORMAL, IGNORED

FRAME RLY CONFIG

LMI MODE: OFF, ON, MON

UNIT ID: 000

999

N391: 001 –255, 006
N392: 01– 10, 03
N393: 01– 10, 04
T391: 05 –30, 10
PVC MODE: DIS, EN

SOS TX: EN, DIS

SOS RX: EN, DIS

UTILITIES

VERSION: z.zz
RESTORE FACTORY?

SET PASSWORD

*

:

Figure 4.2

DDS CSU/DSU Menutree

The three-digit current and threshold values (### /###)
range from 000 to 900. An asterisk (*) to the left of these
values indicates that the current value has exceeded the
threshold value. Pressing SELECT on a displayed alarm
allows editing the threshold parameters for that alarm.

The values are shown as (sss/ttttt). The 15-
minute current value (sss) ranges from 000
to 900. The 24-hour total values (ttttt) range
from 00000 to 65535.

(Install mode only) If the DLCI TOTAL is greater than

000, a screen with the following format appears when
SELECT is pressed:

uuuu -> vvvv:www

xxxxms yyyykbps

uuuu - the local DLCI number
vvvv - ACT., IDLE, NEW, DEL., or REMOTE DLCI (if

discovered)

www - remote unit ID
xxxx - average delay (if discovered)
yyyy - committed information rate

*

This field establishes the unit password used for entering
the front panel interface. A password must be eight
characters. SCROLL increments the characters (0 –9, A –

Z, a– z). The cursor blinks over the character or digit to be

selected or modified. SELECT accepts the current value
and moves the cursor right. When the eighth character is
selected, a verification screen appears. Reenter the
password.

Monitor option only

§

This does not apply to frame relay alarms.

Default values are shown in bold.

1

The network configuration is automatically set when the
DTE Rate is set. For example, 56 Kbps DTE Rate sets the
network to DDS I and 64 Kbps DTE Rate sets the network
to DDS II CC 64K.