Esf registers, Esf registers -13 – Verilink AS100 (896-502379-001) Product Manual User Manual
Page 87

Access System Centum Series User Manual
6-13
ESF Registers
From the terminal’s Main Menu, the user has selected ESF Registers and
is presented with the following menu.
The user can then proceed to this next menu for detailed information.
These menus provide the functions described in Alarms and Statistics, on
page 5-1.
Add 1 screen
Verilink Corporation Mar 18, 1995
Access System 150 T-1 Drop-and-Insert CSU/DSU 20:26:00
Unit ID: 30000000
ESF Registers
ESF Statistics
Register Current 24 Hour
Errored Seconds.........: 000 00001
Failed Seconds (UAS)....: 000 00000
Severely Errored Seconds: 000 00001
Bursty Errored Seconds..: 000 00000
Loss of Frame Count.....: 000 00000
Time in Interval........: 150
# Valid Intervals.......: 093
ESF Status..............: 00000000
Display ESF Network Registers = [R]
Return to Previous Menu = [X]