Verilink AS100 (896-502379-001) Product Manual User Manual
Page 42
Configuring and Installing the Centum Series
3-18
Access System Centum Series User Manual
22.
PBX distance.
Repeatedly
SELECT
to choose a distance figure that most closely
approximates the cable length from the DSX-1 port to the PBX.
23.
DSX-1 CFA.
Repeatedly
SELECT
to choose No or Yes.
Yes causes the Centum Series unit to pass “red alarm” signals to the
PBX for appropriate action.
Refer to NI CFA, item #9, earlier.
If NI CFA is Yes, choose DSX-1 CFA No.
If NI CFA is No and the network is provided by a common carrier,
such as a telephone company, choose DSX-1 CFA Yes. Ensure that
the attached PBX will react to a three-second “red alarm” by
discarding data and sending a “yellow alarm”.
If NI CFA is No and the network is private, the selection is a user
option.
DSX-1 Config.
DSX-1 CFA:_XX
DOWN
to
display: