Configuring and Installing the Centum Series
3-26
Access System Centum Series User Manual
If the remote end responds properly to this command, the DSX-1/NI
LOOP
indicator will illuminate within approximately ten seconds. If the
remote end does not respond properly, the
LOOP
indicator will remain
extinguished and the LCD panel will change to NI RLB..:_Off.
Confirm that the remote end has responded properly. If it has not, check
the NI cable connections and try again. If it still does not respond,
contact your network supplier. Continue with the following steps only if
the remote end has responded properly.
Confirm that the Seconds/Test is properly incrementing and then depress
UP
to confirm that the Errored Seconds is not incrementing. If the unit
is receiving errored seconds, confirm your configuration and run the
testing again. If the unit still indicates errored seconds, contact our
Technical Assistance Center.
Turn Off the BERT and the Loop. Your system is now ready for
operation.
NI/DSX-1 Diag.
BERT......:_On
quired and
to display:
NI/DSX-1 Diag.
Err Secs.:_
∅∅∅∅∅
quired and
to display:
NI/DSX-1 Diag.
Sec/Test.:_
∅∅∅∅∅
quired and
to display: