Verilink AS100 (896-502379-001) Product Manual User Manual
Page 46

Configuring and Installing the Centum Series
3-22
Access System Centum Series User Manual
Confirm that the Seconds/Test is properly incrementing and then depress
UP
to confirm that the Errored Seconds is not incrementing. If the unit is
receiving errored seconds, confirm your configuration and run the self-
testing again. If the unit still indicates “errored seconds”, contact our
Technical Assistance Center.
Turn Off the BERT and the CSU Loop.
Cycle through the Diagnostics menus and confirm that all test functions
(loops and BERT) are Off. (If necessary, turn them Off).
If the unit is being used in a point-to-point configuration, configure and
self-test the remote unit. If the unit is being used in an Integrated Access,
Fractional T1 environment, configure and self-test all remaining units.
NI/DSX-1 Diag.
BERT......:_Off or On
to display:
NI/DSX-1 Diag.
BERT......:_On
SELECT
to display:
NI/DSX-1 Diag.
Err Secs.:_
∅∅∅∅∅
quired and
to display:
NI/DSX-1 Diag.
Sec/Test.:_
∅∅∅∅∅
quired and
to display: