Appendix D: Automatic Fail-Over Option
For applications in need of an Automatic Fail-Over system, Thinklogical offers a solution to 
meet this need. This option allows for two separate fiber paths and the ability to select which of 
the two paths is the viable path. This feature is available on the transmitter unit only. 
The transmitter contains all the same features as the standard Velocity products in addition to 
offering a redundant fiber connector (L1’) for each standard fiber connector (L1). All other 
features function as described previously in the manual. 
Velocity 3 TX with Automatic Fail-Over
Fiber Connections 
L1 and L1' are redundant outputs, outputting the same video and KMASS data. 
 
L2 and L2' are redundant back-channel KMASS data inputs. There is an internal MUX which 
selects L2 or L2' data. When the unit is powered on, it will select L2 first (if L2 is active). 
Otherwise, it will select L2' (if L2' is active). It will only switch from L2 to L2' if L2 is inactive and 
L2' is active. It will only switch from L2' to L2 if L2' is inactive and L2 is active. 
 
Velocitydvi-3 Transmitter with Automatic Fail-Over
 
 