Dde control cvs – SoundTraxx Tsunami Steam Technical Reference User Manual
Page 86

Tsunami Technical Reference
Page 84
CV 188 DDE Tracking Coefficient
Bits 0-7:
D0:D7, DDE Tracking Coefficient
This CV contains a value between 0 and 255 that sets
the no load sense level for the DDE controller when
back-EMF is disabled, as a percentage of the track
voltage.
Tracking Coefficient = CV Value÷128
Default Value:
102 (80%)
Bit 7
Bit 0
D7
D6
D5
D4
D3
D2
D1
D0
DDE Control CVs