Page 8
CV 11
Packet Time Out Value
Description
Contains a value between 0 and 255 corresponding to the time period that is
allowed to elapse between receipts of a valid packet addressed to the DSD
before a throttle shutdown occurs.
D0-D7: Packet Time-out Value
The time out period is computed in seconds as:
Time Out Period = CV 11 X 0.25
A CV value of 0 disables the time out period and the locomotive will run
indefinitely without receiving another packet.
For all other values, the DSD maintains an internal timer, which is reset every
time the DSD receives a valid broadcast address packet or other valid packet
whose address matches its primary address or, if enabled, the extended
address or consist address.
In the event no valid packets are received within the prescribed time period,
the DSD will bring the locomotive to a stop at the rate set by CV 4 and CV
24. The state of the auxiliary function outputs will remain unchanged.
Default value:
0
Bit 7
Bit 0
D7
D6
D5
D4
D3
D2
D1
D0
Primary CVs