beautypg.com

Primary cvs, Cv 2 vstart, Description – SoundTraxx Tsunami Steam Technical Reference User Manual

Page 4

background image

Tsunami Technical Reference

Page 2

CV 2
Vstart

Description

Vstart defines the initial voltage level applied to the motor at speed step 1 as

a fraction of available supply voltage:

D0-D7: Motor Start Voltage

Vstart may contain any value from 0 to 255. The starting voltage applied to

the motor may be computed as:

Starting Voltage = Supply Voltage X CV2÷255

where CV 2 is the contents of the Vstart register. A value of 0 corresponds to

a zero starting voltage. A value of 255 corresponds to the maximum available

voltage (100%).

For speed steps greater than 1, the DSD will continue to sum the initial

starting voltage level into the throttle computations which has the effect of

offsetting all points on a given speed curve by the level set by Vstart as

illustrated in the figure below.

Default value:

0

Primary CVs

Bit 7

Bit 0

D7

D6

D5

D4

D3

D2

D1

D0

0

2

4

6

8

10

12

14

16

18

20

22

24

28

SPEED STEP

Vstart = 20

Vstart = 0

MO

TOR

V

O

LT

A

G

E

100%

75%

50%

25%

0%