Troubleshooting

temperature has fallen back to a safe level. An Over-temperature fault is

usually due to inadequate ventilation or using a motor load that exceeds

the decoder’s rating.

Error 10 - Over voltage fault

An Over-voltage fault indicates that the track voltage is greater than 22

volts. When this error occurs, motor control and sound will be shut off

and the error code will continue to flash until the voltage is brought below

22 Volts. Note: Tsunami’s absolute maximum voltage input is 27 volts!

Track voltages exceeding 27 volts may cause permanent damage to the

decoder.

Error 11 - Motor Connection Fault

This error indicates a faulty motor connection has been detected and

typically occurs when the motor lead is shorted to a track pickup wire.

The motor will not respond until the error is corrected.

Error 12 - Motor Overload Fault

This error indicates the motor load has exceeded the decoder’s current

rating. Supported on Models TSU-4000 and TSU-8000 only.

Error 16 - CVS reset to default

This code is informational only and indicates that all CVs have been reset

to their factory defaults.

On rare occasion, the Tsunami Decoder may also report the following error

codes which cannot be remedied by the user and require a return to the

factory for repair:

Error 1 - COP Fault

Error 2 - Software Fault

Error 5 - EEROM Checksum failure

Error 6 - Lower Calibration Voltage Error

Error 7 - Upper Calibration Voltage Error

If you are still having difficulties, contact our customer service department for

guidance.